6 findings shown, ordered by impact on production and cost.

HighActive nowInsulation resistance condition91%High confidence

Persistent insulation resistance condition on Ring3 Inverter 1

Ring3 Inverter 1 has been underperforming since 1 February. The most likely cause is an insulation resistance problem. Estimated production loss is approximately 3.2 MWh.

Location
Apollo2_New · Ring3_Inverter1
Estimated loss
3,204 kWh
Financial impact
€352
Duration
31 days

Next step: Inspect DC cabling and connectors on the affected strings for moisture and damage

MediumActive nowMPPT imbalance64%Moderate confidence

Possible MPPT imbalance on Ring3 Inverter 2

Variation between active MPPT energy measurements is approximately 16.5%. This is an investigation candidate rather than a confirmed fault.

Location
Apollo2_New · Ring3_Inverter2
Estimated loss
486 kWh
Financial impact
€53
Duration
26 days

Next step: Compare string layout and orientation against the design documentation

MediumActive nowTemperature anomaly76%Moderate confidence

Elevated internal temperature on Ring4 Inverter 2

Internal temperature runs 12 to 16 degrees above comparable inverters during peak hours, with small derating episodes at midday.

Location
Apollo2_New · Ring4_Inverter2
Estimated loss
138 kWh
Financial impact
€15
Duration
9 days

Next step: Inspect and clean ventilation paths and filters

LowActive nowMPPT imbalance58%Low confidence

Possible MPPT imbalance on Ring2 Inverter 1

Variation between active MPPT energy measurements is approximately 11.4%. Worth inspecting during the next site visit.

Location
Apollo2_New · Ring2_Inverter1
Estimated loss
264 kWh
Financial impact
€29
Duration
19 days

Next step: Add a visual check of this array to the next scheduled site visit

LowNot activeMissing data99%High confidence

Missing measurement intervals on Ring1 Inverter 2

409 five minute intervals are missing for this device on 18 and 19 February. This is a data quality issue and not an equipment fault.

Location
Apollo2_New · Ring1_Inverter2
Estimated loss
0 kWh
Financial impact
€0
Duration
34 h

Next step: Re-export the period from the monitoring platform if the raw data is required

InformationNot activeUnexpected shutdown42%Low confidence

Shutdown records reviewed at HPP Banja rooftop

Both rooftop reference inverters recorded a high number of shutdown entries. Most of them occur around sunrise and sunset and are normal behaviour.

Location
HPP Banja 50kW Rooftop · Site level
Estimated loss
12 kWh
Financial impact
€1
Duration
Recurring

Next step: No action required at this time