Low58%Low confidenceActive nowMPPT imbalanceINC-1064

Possible MPPT imbalance on Ring2 Inverter 1

Variation between active MPPT energy measurements is approximately 11.4%. Worth inspecting during the next site visit.

Apollo2_New · Ring2_Inverter1 · Started 12 Feb 2025, 10:15

Estimated energy loss

264kWh

Estimated financial loss

€29

Current loss rate

1.8kW

Duration

19 days

Recommended action

Add a visual check of this array to the next scheduled site visit

Why SOL detected this

  • Spread between active MPPT inputs is 11.4%.
  • The gap widens in the morning and narrows after midday.
  • No fault codes were reported by this device.

Most likely cause

Moderate difference between MPPT inputs, most likely soiling or partial shading on one string group.

Other possible causes

  • Soiling on part of the array
  • Partial shading in the morning hours
  • Small module mismatch
  • Design difference between string groups

Recommended inspection

These steps become the technician checklist

  1. 1Add a visual check of this array to the next scheduled site visit
  2. 2Review morning shading from nearby structures
  3. 3Clean the affected string group if soiling is present

Actual against expected power

Peer comparison for a representative day

Expected against actual power

Units: kW by time of day

What to notice: The dashed line is what comparable inverters produced at the same time. The shaded area is the actual output.