SAVA Demo data

Reports

Reporting period: 1 February to 3 March 2025.

Energy produced

223.5MWh

Performance against potential

96.8%

Value of lost production

€593

Recovered through maintenance

€115

Daily production and losses

Actual output with the shortfall stacked above

Daily energy against expectation

Units: kWh per day

What to notice: Each bar is one day at Apollo2_New. The pale band is energy the plant should have produced but did not.

Where the losses came from

Grouped by the kind of problem SOL detected

  • Insulation resistance condition

    1 findings

    3,204 kWh

    €352

  • Underperformance

    1 findings

    1,145 kWh

    €126

  • MPPT imbalance

    2 findings

    750 kWh

    €83

  • Site wide shutdown

    1 findings

    142 kWh

    €16

  • Temperature anomaly

    1 findings

    138 kWh

    €15

  • Unexpected shutdown

    1 findings

    12 kWh

    €1

  • Missing data

    1 findings

    0 kWh

    €0

Site summary

Actual against expected energy for the period

Site performance summary
SiteActualExpectedAvailabilityHealth
Apollo2_New214.6 MWh223.8 MWh98.1%88
HPP Banja 50kW Rooftop8.9 MWh9 MWh99.4%96

Findings in the period

Everything SOL raised, with the date it began

  • Persistent insulation resistance condition on Ring3 Inverter 1

    01 Feb 2025 · Apollo2_New

    High€352
  • Site wide shutdown detected at Apollo2_New

    10 Feb 2025 · Apollo2_New

    Medium€16
  • Possible MPPT imbalance on Ring3 Inverter 2

    06 Feb 2025 · Apollo2_New

    Medium€53
  • Possible MPPT imbalance on Ring2 Inverter 1

    12 Feb 2025 · Apollo2_New

    Low€29
  • Shutdown records reviewed at HPP Banja rooftop

    01 Feb 2025 · HPP Banja 50kW Rooftop

    Information€1
  • Missing measurement intervals on Ring1 Inverter 2

    18 Feb 2025 · Apollo2_New

    Low€0
  • Elevated internal temperature on Ring4 Inverter 2

    22 Feb 2025 · Apollo2_New

    Medium€15
  • String underperformance on Ring1 Inverter 3

    08 Feb 2025 · Apollo2_New

    Medium€126