MediumVerifiedTASK-198
Repair open string on Ring1 Inverter 3
One MPPT input showed near zero current. Locate and repair the open circuit.
Apollo2_New · Ring1_Inverter3 · due 21 Feb 2025 · INC-0996
Before you start
Isolate and verify zero voltage before working on DC conductors.
Inspection checklist
4 of 4 steps complete
Repair report
Attach photographs of the repair (available on the mobile app).
Repair recorded on 21 Feb 2025.
Repair verification
SOL compares the equipment before and after the repair to confirm the fix held
Performance before
82%
Performance after
99%
Energy recovered
1,042kWh
Performance before and after maintenance
Units: Percent of expectation
What to notice: Each measure is expressed as a percentage of what comparable equipment achieved.
Ring1 Inverter 3 is now operating within 1% of comparable inverters. The low string current condition has not returned during the verification period.