Medium88%High confidenceNot activeUnderperformanceINC-0996

String underperformance on Ring1 Inverter 3

Output was 18% below comparable inverters between 8 and 21 February. A disconnected string was found and repaired.

Apollo2_New · Ring1_Inverter3 · Started 08 Feb 2025, 08:10

Estimated energy loss

1,145kWh

Estimated financial loss

€126

Current loss rate

Not active

Duration

13 days

Recommended action

Replace the failed connector

Why SOL detected this

  • Output was 18% below the Apollo peer median during daylight.
  • One MPPT input showed near zero current while the others were normal.
  • The pattern started abruptly on 8 February.

Most likely cause

Open circuit on one string caused by a failed connector.

Other possible causes

  • Failed DC connector
  • Blown string fuse
  • Module failure

Recommended inspection

These steps become the technician checklist

  1. 1Replace the failed connector
  2. 2Verify string current after repair

Actual against expected power

Peer comparison for a representative day

Expected against actual power

Units: kW by time of day

What to notice: The dashed line is what comparable inverters produced at the same time. The shaded area is the actual output.